A Network fire alarm system alerts people when smoke, fire, other fire-related crises are noticed. These warnings may be activated automatically from smoke detectors, and heat detectors or may also be begun via manual fire alarm activation instruments such as manual call points and pull stations.
They can also be speaker strobes that express an alarm, observed by a voice evacuation notice which alerts people inside the establishment not to utilize the elevators.
Network Fire alarm sounders can be arranged to certain frequencies and various tones including low, medium, and high, relying on the country and manufacturer of the instrument.
Network Fire alarm electronic instruments are known as horns. Fire alarm alert instruments can also be set to various volume levels.
Parts of Network Alarm System:
An important component of any fire alarm is the control panel. Large buildings have control panels distributed on various floors of different buildings.
In a networked system, control panels communicate with one another, allowing individual panels to maintain control of their own points while also checking points physically connected to other panels.
This allows you to view the entire system from a central location, which can be helpful in various situations.
The function of a fire alarm system is to detect fires and alert both building residents and emergency personnel from a centrally monitored and controlled location.
These systems also self-monitor, identifying where within the building alarms originate from and detecting when errors
appear in wiring and connections that may hinder the system from working accurately.
In a large infrastructure or building, fire alarm systems, networking simply makes sense. Here’s we brief on how you get to benefit from installing network solutions in your facility
When you can see the entire alert reporting from a single integrated dashboard, your ability to command and control a large, complex fire alarm becomes easier and more prompt.
The return on investment from installing a networked fire alarm stems from a reduction in annual monitoring costs. Standalone systems generally require two transmission channels and a central station monitoring agreement per system. Otherwise, networked solutions only need single transmission channel/monitoring agreement for your entire building.
If a single panel loses communication, all remaining panels continue to communicate with each other. This way, no single component can take out the entire system, making it more robust.
This elective feature of a networked fire alarm lets you monitor activity and view information remotely with the appropriate computer software from your client-server as well.
We can pull up logs and records as well as review previous upgrades and reports of false alarms for all connected devices from the central dashboard and can store the historical backup in any external device.
If you select to include emergency communications with your networked alarm system, it can serve as or integrated with your existing mass notification system to deliver critical messages to nominated people or groups of your company in an emergency.
At DGS, we offer design/build services for networked fire alarms. We install Addressable control panels, one of today’s most trusted brands e.g. Honeywell, Mircom, Siemens, Agni, GST, and notifier Fire System.
In addition to our top-of-the-line products, we also offer professional services, including CAD drawings, to make sure the installation suits your facility’s fire protection needs to the fullest. We are a certified company with the best fire alarm system designers and technicians in the North with our team.
Contact us today to request an estimate for our design and installation services.
Network Fire alarm systems play a crucial role in the detection of fire. All premises must be equipped with the right fire detection system according to fire alarm safety regulations.
With an effective fire alarm system installed in your building, any fire attack will be detected easily, and residents alerted within a short period
Practicably you already have networking solutions hard at work for your facility. However, you still you need system inspections and repairs to keep the equipment in proper working order.
We maintain and fix all parts of a networked fire alarm, including fire control panels, smoke detectors, heat detectors, MCP, horns, strobe lights, and more.
After an inspection of your fire alarm, we will let you know if we find anything in need of repair before we service the equipments. This way, you never caught off-guard by surprising costs.
If you notice something’s wrong with your networked fire alarm system, or it’s simply time for your next inspection, please do contact DGS to schedule services today.
We also offer 24/7 emergency fire alarm repairs when you need us most.
Networked fire alarms are installed in large commercial campuses with high-rise offices or multiple buildings. It is designed to simplify the usability and control of your fire alarm. Thanks to the network solutions available from Damia Global Services., you can!
To learn more about our fire alarm network solutions, please contact us at +917009252789.